Isolated Complete Rupture of the Biceps Femoris Insertion: A Surgical Repair Technique Manuscript

We describe a knotless suture anchor fixation technique for this tear pattern. At surgery, the retracted biceps tendon and insertion site is debrided to healthy tissue, FiberTape suture (Arthrex) is passed in a Kracków fashion through the tendon, and the 2 ends of the suture are brought down to a SwiveLock anchor (Arthrex) at the anatomic insertion. FiberWire sutures (Arthrex) from the anchor are brought over the remnant stump, completing the repair.
Source: Arthroscopy Techniques - Category: Surgery Source Type: research