A Formula for Estimating the Appropriate Tube Depth for Intubation.

In conclusion, the estimation formulas of (height/10) - 3 + DM and (height/10) + 1 + DM for oral and nasal intubation, respectively, are within almost 1 cm error in most cases. PMID: 30883238 [PubMed - in process]
Source: Anesthesia Progress - Category: Anesthesiology Tags: Anesth Prog Source Type: research