Hernia mesh prevent dislocation after wide excision and reconstruction of giant cell tumor distal radius.

Hernia mesh prevent dislocation after wide excision and reconstruction of giant cell tumor distal radius. World J Orthop. 2017 Sep 18;8(9):741-746 Authors: Wiratnaya IGE, Budiartha IGBAM, Setiawan IGNY, Sindhughosa DA, Kawiyana IKS, Astawa P Abstract Giant cell tumor (GCT) remains as major health problem. GCT which located at the lower end of the radius tends to be more aggressive. Wide excision and reconstruction of the wrist in stage 3 of distal radius GCT lesion is an optimal modality to prevent tumor recurrence. However, dislocation often occurs as its complication. We are reporting patient with GCT of distal radius treated with wide excision and reconstruction using nonvascularized fibular graft and the addition of hernia mesh. Circumferential non-absorbable polypropylene hernia mesh was applied, covered radioulnar joint and volar aspect of radius, and served as additional support to prevent dislocation. During five years and two months of follow-up, we found no dislocation in our patient. Furthermore, good functional outcome was obtained. Our finding suggests that the addition of hernia mesh after wide excision and reconstruction with nonvascularized fibular graft may benefit to prevent dislocation and provides an excellent functional outcome. PMID: 28979859 [PubMed]
Source: World Journal of Orthopaedics - Category: Orthopaedics Tags: World J Orthop Source Type: research