Optimizing a twin-chamber system for direct ozone production rate measurement

Environ Pollut. 2024 Mar 25:123837. doi: 10.1016/j.envpol.2024.123837. Online ahead of print.ABSTRACTHigh Ozone Production Rate (OPR) leads to O3 pollution episodes and adverse human health outcomes. OPR observation (Obs-OPR) and OPR modelling (Mod-OPR) have been obtained from observed and modelled peroxy radicals and nitrogen oxides. However, discrepancies between them remind of an imperfect understanding of O3 photochemistry. Direct measurement of OPR (Mea-OPR) by a twin-chamber system emerges. Herein, we optimized Mea-OPR design, i.e., minimizing the chamber surface area to volume ratio (S/V) to 9.8 m-1 from 18 m-1 and the dark uptake coefficient of O3 to 9.9 × 10-9 from 7.1 × 10-8 in the literature. In addition, control experiments further revealed and quantified a photo-enhanced O3 uptake, and therefore recommended an essential correction of Mea-OPR. We finally characterized a measurement uncertainty of ±38% and a detection limit of 3.2 ppbv h-1 (3SD), which suggested that Mea-OPR would be sensitive enough to measure OPR in urban or suburban environments. Further application of this system in urban Beijing during the Beijing 2022 Olympic Winter Games recorded a noontime OPR of 7.3 (±3.3, 1SD) ppbv h-1. These observational results added up to our confidence in future field application of Mea-OPR, to facilitate pollution control policy evaluation and to shed light on O3 photochemistry puzzle.PMID:38537793 | DOI:10.1016/j.envpol.2024.123837
Source: Environmental Pollution - Category: Environmental Health Authors: Source Type: research