Standardized acquisition and documentation of cine loops on conventional thyroid ultrasound

Laryngorhinootologie. 2023 Nov 13. doi: 10.1055/a-2192-4039. Online ahead of print.ABSTRACTUltrasound is the basic imaging method for the assessment of the thyroid gland. Due to the high prevalence of structural disease, the examination procedure is used very frequently in Germany, in many cases in the context of follow-up. The assessment of thyroid pathologies and their dynamics is subjected to relevant inter- and intraobserver variability. Findings that were not identified during live ultrasound cannot be assessed retrospectively. Applying an SOP for the acquisition and documentation of standardized video sequences of ultrasound images (so-called cine loops), allows for a secondary retrospective evaluation of the thyroid gland, taking into account previously acquired images analogous to other cross-sectional imaging methods such as CT or MRI. The cine loops can be acquired by non-physician personnel, stored to the local PACS and used for educational and research purposes.PMID:37956975 | DOI:10.1055/a-2192-4039
Source: Nuklearmedizin - Category: Radiology Authors: Source Type: research