Biomechanical Comparison of Distal Radioulnar Joint Reconstruction Graft Preparation Techniques

Conclusions In this biomechanical study, augmentation of porcine tendons with suture spaced at either 6 or 12 mm for DRUJ reconstruction significantly increased survival to a staircase cyclic loading protocol Clinical Relevance For the Adams–Berger reconstruction, tendon grafts augmented along their entire length by nonabsorbable braided suture are biomechanically superior to tendon alone. [...] Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USAArticle in Thieme eJournals: Table of contents  |  Abstract  |  Full text
Source: Journal of Wrist Surgery - Category: Orthopaedics Authors: Tags: Scientific Article Source Type: research