Rupture of the Flexor Pollicis Longus Tendon Involved between the Radial Shaft and the Volar Locking Plate

We report the case of a 61-year-old woman with right-sided flexor pollicis longus (FPL) tendon ruptured a month after volar locking plate fixation. Five months after the initial operation, hardware removal and reconstruction of the FPL tendon with the ipsilateral palmaris longus were performed. The proximal stump of the ruptured FPL tendon was found in the space between the distal radius and plate. [...] Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USAArticle in Thieme eJournals: Table of contents  |  Abstract  |  Full text
Source: Journal of Wrist Surgery - Category: Orthopaedics Authors: Tags: Case Report Source Type: research