Novel scoring system derived from meta ‐analysis and validated in cohort population for predicting 1‐year atrial fibrillation recurrence after cryoballoon catheter ablation: The HeLPS‐Cryo score
ConclusionThe HeLPS-Cryo score can help the physician estimate the probability of 1-year AF recurrence after the successful CBCA procedure. Patients with HeLPS-Cryo score  <3 are good candidates for the CBCA procedure. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 25, 2024 Category: Cardiology Authors: Yoga Waranugraha, Jung ‐Chi Hsu, Ting‐Tse Lin, Li‐Ting Ho, Chih‐Chieh Yu, Yen‐Bin Liu, Lian‐Yu Lin Tags: ORIGINAL ARTICLE Source Type: research

Ion channel dysfunction and fibrosis in atrial fibrillation: Two sides of the same coin
AbstractBackgroundAtrial fibrillation (AF) is a common heart rhythm disorder that is associated with an increased risk of stroke and heart failure (HF). Initially, an association between AF and ion channel dysfunction was identified, classifying the pathology as a predominantly electrical disease. More recently it has been recognized that fibrosis and structural atrial remodeling play a driving role in the development of this arrhythmia also in these cases.PurposeUnderstanding the role of fibrosis in genetic determined AF could be important to better comprise the pathophysiology of this arrhythmia and to refine its managem...
Source: Pacing and Clinical Electrophysiology : PACE - February 20, 2024 Category: Cardiology Authors: Gianmarco Arabia, Maria Giulia Bellicini, Angelica Cersosimo, Maurizio Memo, Francesco Mazzarotto, Riccardo Maria Inciardi, Manuel Cerini, Lin Yee Chen, Mohamed Aboelhassan, Patrizia Benzoni, Gianfranco Mitacchione, Luca Bontempi, Antonio Curn Tags: REVIEW Source Type: research

Ser194Leu DSG2 mutation, associated with arrhythmogenic left ventricular cardiomyopathy and ventricular tachycardia
ConclusionSer194Leu is a missense pathogenic mutation of DSG2 gene associated with arrhythmogenic left ventricular cardiomyopathy. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 20, 2024 Category: Cardiology Authors: Miry Blich, Yaniv Zohar, Victoria Cohen ‐Kaplan, Irina Minkov, Rabea Asleh, Smadar Horowitz, Karin Weiss, Tamar Paperna, Jonathan Lessick, Sobhi Abadi, Asaad Khoury, Lior Gepstein, Mahmud Suleiman, Oren Caspi Tags: ELECTROPHYSIOLOGY Source Type: research

Issue Information
(Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 14, 2024 Category: Cardiology Tags: ISSUE INFORMATION Source Type: research

Cannon A wave validation as a diagnostic tool in paroxysmal supraventricular tachycardias
ConclusionThe presence of cannon A waves is associated with the final diagnosis of short VA interval tachycardias. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 14, 2024 Category: Cardiology Authors: David Gonz ález‐Casal, Alberto Pérez‐Castellanos, Nina Soto Flores, Alejandro Carta‐Bergaz, Esteban González‐Torrecilla, Vanesa Bruña Fernández, Pablo Ávila, Felipe Atienza, Ángel Arenal, Jorge González‐Panizo, Francisco Ferná Tags: ELECTROPHYSIOLOGY Source Type: research

Proceed with caution: Standard protocol exercise stress tests fail to replicate the diagnostic utility of supine ‐stand tests for long QT syndrome
ConclusionTESTs should be used with caution when trying to interpret supine-stand changes for diagnosis of LQTS. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 13, 2024 Category: Cardiology Authors: Alexa M. Pinsky, Veda K. Kulkarni, J. Martijn Bos, Raquel Neves, Thomas G. Allison, Michael J. Ackerman Tags: ORIGINAL ARTICLE Source Type: research

Aveir retrievable, 38 ‐mm length, leadless pacemaker implantation in a 23‐kg pediatric patient with congenital heart disease
ConclusionAveir retrievable leadless pacemakers can be implanted safely in a child with tetralogy of Fallot, as small as 23 kilograms. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 12, 2024 Category: Cardiology Authors: Jacob Rodriguez, Daniel Cortez Tags: DEVICES Source Type: research

Wide QRS tachycardia: What is the mechanism?
(Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 11, 2024 Category: Cardiology Authors: Krishna Kishore Umapathi, Hemal M. Nayak, Utkarsh Kohli Tags: EP ROUNDS Source Type: research

Utility of routine follow ‐up defibrillation safety margin testing in young patients with epicardial implantable cardioverter‐defibrillators
ConclusionsOur data suggest that epicardial ICDs are reliable and routine follow-up DSM testing may not be necessary for all patients. DSM testing should be performed in individuals with epicardial ICD systems when there is clinical concern about lead or coil performance. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 11, 2024 Category: Cardiology Authors: Tomas Leng, Elaine Griffeth, Elizabeth H. Stephens, Joseph A. Dearani, Bryan C. Cannon, Michael J. Ackerman, Philip L. Wackel Tags: ELECTROPHYSIOLOGY Source Type: research

Efficacy and safety of pulsed field ablation for atrial fibrillation: A systematic review and meta ‐analysis
(Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 11, 2024 Category: Cardiology Authors: Usama Qamar, Siddharth Agarwal, Satyam Krishan, Abhishek Deshmukh, Christopher V. DeSimone, Stavros Stavrakis, Jonathan P. Piccini, Zain Ul Abideen Asad Tags: BRIEF COMMUNICATION Source Type: research

False ‐positive alarms in patients with implantable loop recorder followed by remote monitoring: A systematic review
AbstractRemote Monitoring (RM) has been shown to provide useful information about arrhythmic events in patients with implantable loop recorders (ILRs), however there is few and conflicting data about the false positive (FP) alarms burden and characteristics among ILR recipients. The aim of the present systematic review was to evaluate incidence and characteristics of FP alarms among ILR patients followed by RM. We developed a systematic research in Embase, MEDLINE and PubMed databases and selected all papers focused on false positive ILR transmissions published from June 01, 2013 to June 01, 2023. Case reports, meeting sum...
Source: Pacing and Clinical Electrophysiology : PACE - February 11, 2024 Category: Cardiology Authors: Simona Covino, Vincenzo Russo Tags: REVIEW Source Type: research

Histological and functional assessment of a Takotsubo cardiomyopathy model established by immobilization stress
ConclusionsOur study confirms the hypothesis that IMO stress can mimic Takotsubo cardiomyopathy, and the various effects on the heart depending on the duration of IMO stress. We observed the highest incidence of TTC occurred after 5 days of stress. Furthermore, there is a gradual occurrence of electrical and structural remodeling as the stress duration prolongs. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 11, 2024 Category: Cardiology Authors: Quanwei Pei, Jiemei Yang, Bin Li, Pengqi Lin, Lina Zou, Junpei Zhang, Hongpeng Yin, Jingmei Sun, Xin Wang, Nevzorova Vera A, Zengxiang Dong, Dechun Yin Tags: ELECTROPHYSIOLOGY Source Type: research

Permanent pacemaker implantation with hybrid endocardial perventricular approach in infancy: May be an alternative route in the absence of epicardial lead
AbstractDespite the advancements in technology, establishing the optimal implantation technique for pediatric patients with a pacemaker (PM) indication remains challenging. Although the implantation of an epicardial PM is recommended, especially in children weighing less than 10  kg, transventricular placement of endocardial leads can be performed safely, offering a practical substitute for an epicardial pacing system, particularly in situations where a transvenous approach is unfeasible due to patient size, anatomical constraints or epicardial PM leads were not available as in our case. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 11, 2024 Category: Cardiology Authors: Yakup Ergul, Gulhan Tunca Sahin, Hasan Candas Kafali, Ismihan Selen Onan Tags: CASE REPORT Source Type: research

Effect of age on in ‐hospital outcomes of transvenous lead extraction for infected cardiac implantable electronic device
ConclusionElderly patients had worse in-hospital outcomes in early mortality and non-home discharge following the TLE for infected CIED. There was no significant difference between elderly and non-elderly groups in prolonged hospital stay and 30-day readmission. Elderly patients did not have a higher risk of procedural complications. (Source: Pacing and Clinical Electrophysiology : PACE)
Source: Pacing and Clinical Electrophysiology : PACE - February 7, 2024 Category: Cardiology Authors: Min Choon Tan, Qi Xuan Ang, Yong Hao Yeo, Jia Yean Thong, Aneesh Tolat, Luis R. Scott, Justin Z. Lee Tags: ORIGINAL ARTICLE Source Type: research

Chronic phase subcutaneous implantable cardioverter defibrillator lead dislodgement in a patient with arrhythmogenic right ventricular cardiomyopathy
AbstractThe subcutaneous implantable cardioverter defibrillator (S-ICD) is often used in young patients such as arrhythmogenic right ventricular cardiomyopathy (ARVC) and Brugada syndrome due to long-term lead durability issues. Although S-ICD lead dislodgement is rare, we encountered such an incident in a young ARVC patient during the chronic phase following the two-incision technique. Remote monitoring system is useful for early diagnosis of electrode movement (Graphical abstract image). When S-ICD lead dislodgement occurs in active young patients, lead revision using the three-incision technique may be an option. (Sourc...
Source: Pacing and Clinical Electrophysiology : PACE - February 6, 2024 Category: Cardiology Authors: Ryuki Chatani, Hiroshi Tasaka, Atsushi Sakata, Mitsuru Yoshino, Kazushige Kadota Tags: CASE REPORT Source Type: research