A 3D dual-echo spiral sequence for simultaneous dynamic susceptibility contrast and dynamic contrast-enhanced MRI with single bolus injection
CONCLUSION: A 3D dual-echo spiral technique was developed to simultaneously acquire both DSC and DCE data in a single-bolus injection with reduced contrast use. Preliminary volunteer and patient data demonstrated increased temporal SNR, reduced geometric artifacts, and accurate perfusion quantification, suggesting a competitive alternative to SOC-EPI techniques for brain perfusion MRI.PMID:38469930 | DOI:10.1002/mrm.30077 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 12, 2024 Category: Radiology Authors: Zhiqiang Li Dinghui Wang Melvyn B Ooi Poonam Choudhary Sudarshan Ragunathan John P Karis James G Pipe C Chad Quarles Ashley M Stokes Source Type: research

Intra-scan RF power amplifier drift correction
CONCLUSION: Utilizing DICO recordings and implementing a feedback mechanism enable the prospective correction of RFPA drift. Having a calibration scan, predictive correction can be utilized with fewer complexity; for enhanced performance, a run-time approach can be employed.PMID:38469935 | DOI:10.1002/mrm.30078 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 12, 2024 Category: Radiology Authors: Ali Aghaeifar Dario Bosch Rahel Heule Sydney Williams Philipp Ehses Franck Mauconduit Klaus Scheffler Source Type: research

Inline automatic quality control of 2D phase-contrast flow MRI for subject-specific scan time adaptation
CONCLUSION: The inline quality control enables subject-specific optimized scan times while ensuring consistent diagnostic image quality. The distribution of automated stopping times across the population revealed the value of a subject-specific scan time.PMID:38469944 | DOI:10.1002/mrm.30083 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 12, 2024 Category: Radiology Authors: Pierre Daud é Rajiv Ramasawmy Ahsan Javed Robert J Lederman Kelvin Chow Adrienne E Campbell-Washburn Source Type: research

High-field downfield MR spectroscopic imaging in the human brain
CONCLUSION: High-field DF-MRSI is able to spatially map exchangeable protons in the human brain at high resolution and with near whole-brain coverage in acceptable scan times, and in the future may be used to study metabolism of brain tumors or other neuropathological disorders.PMID:38469953 | DOI:10.1002/mrm.30075 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 12, 2024 Category: Radiology Authors: İpek Özdemir Semra Etyemez Peter B Barker Source Type: research

An extended phase graph-based framework for DANTE-SPACE simulations including physiological, temporal, and spatial variations
CONCLUSION: The presented simulation framework facilitates a more comprehensive optimization of DANTE-SPACE sequence parameters. Furthermore, the simulation framework helps to explain observed contrasts in acquired data.PMID:38469983 | DOI:10.1002/mrm.30071 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 12, 2024 Category: Radiology Authors: Matthijs H S de Buck Peter Jezzard Aaron T Hess Source Type: research

Integrating data distribution prior via Langevin dynamics for end-to-end MR reconstruction
CONCLUSION: The proposed method incorporating Langevin dynamics with end-to-end adversarial training facilitates efficient and robust reconstruction for MRI. Empirical evaluations conducted on brain and knee datasets compellingly demonstrate the superior performance of the proposed method in terms of artifact removing and detail preserving.PMID:38469985 | DOI:10.1002/mrm.30065 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 12, 2024 Category: Radiology Authors: Jing Cheng Zhuo-Xu Cui Qingyong Zhu Haifeng Wang Yanjie Zhu Dong Liang Source Type: research

A theoretical framework to investigate the effect of  high permittivity materials in MRI using anatomy-mimicking cylinders
CONCLUSION: We show how HPM can filter out the modes that only contribute to the noise or RF power deposition, resulting in higher SNR or lower SAR, respectively. Our proposed framework provides physical insight on how to properly design HPM for MRI applications.PMID:38439745 | DOI:10.1002/mrm.30063 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Vincenzo Miranda Giuseppe Ruello Riccardo Lattanzi Source Type: research

Assessment of arterial pulsatility of cerebral perforating arteries using 7T high-resolution dual-VENC phase-contrast MRI
CONCLUSION: Dual-VENC PC-MRI is a reliable imaging method for the assessment of pulsatility of cerebral perforating arteries, which could be useful as a potential imaging biomarker of aging and cSVD.PMID:38440807 | DOI:10.1002/mrm.30073 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Jianing Tang Soroush Heidari Pahlavian Elizabeth Joe Maria Tereza Gamez Tianrui Zhao Samantha J Ma Jin Jin Steven Yong Cen Helena C Chui Lirong Yan Source Type: research

Using a deep learning prior for accelerating hyperpolarized < sup > 13 < /sup > C MRSI on synthetic cancer datasets
CONCLUSION: The proposed singular value decomposition + iterative deep learning model could be considered as a general framework that extended the application of deep learning MRI reconstruction to metabolic imaging. The morphology of tumors and metabolic images could be measured robustly in six times acceleration using our method.PMID:38440832 | DOI:10.1002/mrm.30053 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Zuojun Wang Guanxiong Luo Ye Li Peng Cao Source Type: research

Submillimeter balanced SSFP BOLD-functional MRI accelerated with 3D stack-of-spirals at 9.4 T
CONCLUSIONS: Three-dimensional stack-of-spirals enables passband balanced SSFP functional imaging at a much higher spatial and temporal scale, compared with conventional spoiled gradient-echo train sequences.PMID:38440956 | DOI:10.1002/mrm.30064 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Praveen Iyyappan Valsala Marten Veldmann Dario Bosch Klaus Scheffler Philipp Ehses Source Type: research

Tailored and universal parallel transmit broadband pulses for homogeneous 3D excitation of the human heart at 7T
CONCLUSION: Broadband TP and UP can be used for homogeneous excitation of the heart volume across a 1300 Hz frequency range, including the water and the main six fat peaks, or with longer pulse durations and higher FAs for a smaller transmit bandwidth. Moreover, despite large inter-volunteer variations, broadband UP can be used for calibration-free 3D heart FA homogenization in time-critical situations.PMID:38440957 | DOI:10.1002/mrm.30072 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Christoph Stefan Aigner Sebastian Dietrich-Conzelmann Max Lutz Felix Kr üger Sebastian Schmitter Source Type: research

Age-related differences in macromolecular resonances observed in ultra-short-TE STEAM MR spectra at 7T
CONCLUSIONS: Our findings provide insights into age-related differences in macromolecular contents and strengthen the necessity of using age-matched measured macromolecules during quantification.PMID:38441257 | DOI:10.1002/mrm.30061 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Guglielmo Genovese Melissa Terpstra Pavel Filip Silvia Mangia J Riley McCarten Laura S Hemmy Ma łgorzata Marjańska Source Type: research

GPU-accelerated Bloch simulations and MR-STAT reconstructions using the Julia programming language
CONCLUSION: By combining the proposed Bloch simulation toolbox and the partially matrix-free reconstruction algorithm, 2D MR-STAT reconstructions can be performed in the order of one minute on a modern GPU card. The Bloch simulation toolbox can be utilized for other quantitative MRI techniques as well, for example for online dictionary generation for MR Fingerprinting.PMID:38441315 | DOI:10.1002/mrm.30074 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Oscar van der Heide Cornelis A T van den Berg Alessandro Sbrizzi Source Type: research

Motion-compensated diffusion encoding in multi-shot human brain acquisitions: Insights using high-performance gradients
CONCLUSION: Second-order motion-compensated diffusion encoding mitigates and simplifies shot-to-shot phase variability in the human brain, rendering the multi-shot acquisition strategy an effective means to circumvent limitations of retrospective phase correction methods.PMID:38441339 | DOI:10.1002/mrm.30069 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Eric Seth Michael Franciszek Hennel Klaas Paul Pruessmann Source Type: research

Boosting reproducible research practices with the Repeat It With Me: Reproducibility Team Challenge
Magn Reson Med. 2024 Mar 5. doi: 10.1002/mrm.30041. Online ahead of print.NO ABSTRACTPMID:38441403 | DOI:10.1002/mrm.30041 (Source: Magnetic Resonance in Medicine)
Source: Magnetic Resonance in Medicine - March 5, 2024 Category: Radiology Authors: Laura Bortolotti Sophie Schauman Maria Eugenia Caligiuri Source Type: research