Echocardiographic hemodynamic assessment in decompensated cirrhosis: comparison between Intensivists and Gastroenterologists
Conclusion: Reliability of hemodynamic assessment by gastroenterologists was good, while agreement was unsatisfactory, advocating for further training. Transthoracic echocardiography can differentiate hypovolemia from hyperkinetic states. The role of transthoracic echocardiography in managing decompensated cirrhosis requires further study.Clinical trial number: NCT03650660. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - February 25, 2023 Category: Information Technology Source Type: research

Point of care transthoracic echocardiography for the prediction of post – spinal anesthesia hypotension in elderly patients with cardiac diseases and left ventricular dysfunction
AbstractIn elderly patients with cardiac diseases, changes in cardiovascular physiology diminish cardiovascular reserve and predispose to hemodynamic instability after spinal anesthesia; hence, such patients could be at risk of postoperative complications. Additionally, transthoracic echocardiography (TTE) is used in clinical practice to evaluate cardiovascular hemodynamics. Therefore, we hypothesized that echocardiographic measurements could display significant diagnostic power in the prediction of post - spinal anesthesia hypotension in elderly patients with cardiac diseases and reduced left ventricular ejection fraction...
Source: Journal of Clinical Monitoring and Computing - February 21, 2023 Category: Information Technology Source Type: research

Contrast-enhanced transcranial doppler versus contrast transthoracic echocardiography for right-to-left shunt diagnosis
AbstractRLS can be diagnosed using US, CT angiography, and right heart catheterization. However, most reliable diagnostic modality remains undetermined. c-TCD was more sensitive than c-TTE in the diagnosis of RLS. This was true especially for the detection of provoked shunts or mild shunts. c-TCD can be used as the preferred screening method for RLS. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - February 18, 2023 Category: Information Technology Source Type: research

Associations between clinical interventions and transcutaneous blood gas values in postoperative patients
ConclusionClinical interventions resulted in significant changes in transcutaneous oxygen and carbon dioxide. These findings suggest future studies to assess the clinical value of changes in transcutaneous PO2 and PCO2 in a postoperative setting.Trial registry: Clinical trial number: NCT04735380.Clinical trial registry:https://clinicaltrials.gov/ct2/show/NCT04735380 (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - February 18, 2023 Category: Information Technology Source Type: research

Oxygen saturation in intraosseous sternal blood measured by CO-oximetry and evaluated non-invasively during hypovolaemia and hypoxia – a porcine experimental study
Conclusion: Sternal blood has an oxygen saturation suggesting a mixture of venous and arterial blood. Changes in SsO2 relate well with changes in SvO2 during hypovolaemia or hypoxia. Further studies on the feasibility of using non-invasive measurement of changes in SsO2 to estimate changes in SvO2 are warranted. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - February 14, 2023 Category: Information Technology Source Type: research

Intra-renal microcirculatory alterations on non-traumatic hemorrhagic shock induced acute kidney injury in pigs
In this study, we showed that the correction of systemic hemodynamic variables may not be accompanied with the improvement of renal cortical perfusion, intra-renal blood volume and renal damage following fluid resuscitation. We suggest that the measurement of renal injury biomarkers, systemic and renal microcirculation can be used for guiding to the optimization of fluid therapies. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - February 6, 2023 Category: Information Technology Source Type: research

Software development to standardize the clinical diagnosis of exercise oscillatory ventilation in heart failure
ConclusionThe present study proposes novel semi-automated software to detect EOV in HF, with high inter and intra-rater agreements. The software project and its tutorial are freely available for download. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - February 3, 2023 Category: Information Technology Source Type: research

Missing data imputation techniques for wireless continuous vital signs monitoring
This study explored the performance of various imputation techniques for continuous vital signs measurements. Wireless vital signs measurements (heart rate, respiratory rate, blood oxygen saturation, axillary temperature) from surgical ward patients were used for repeated random simulation of missing data periods (gaps) of 5 –60 min in two-hour windows. Gaps were imputed using linear interpolation, spline interpolation, last observation- and mean carried forwards technique, and cluster-based prognosis. Imputation performance was evaluated using the mean absolute error (MAE) between original and imputed gap samples. B es...
Source: Journal of Clinical Monitoring and Computing - February 2, 2023 Category: Information Technology Source Type: research

Peak systolic myocardial velocity in patients undergoing surgical aortic valve replacement for severe aortic stenosis: prognostic value and natural course
AbstractMyocardial systolic longitudinal function has been known to decrease in patients with severe aortic stenosis (AS). Preoperative peak systolic myocardial velocity at the septal mitral valve annulus (S ’), measured using Doppler tissue imaging, was used as an indicator for myocardial systolic longitudinal function. The prognostic value and natural course of S’ after surgical aortic valve replacement for severe AS have not been elucidated. This retrospective observational study included patient s from January 2006 to December 2018. The patients were divided to 2 groups (pre-S’HIGH vs. pre-S ’LOW) with a cut-of...
Source: Journal of Clinical Monitoring and Computing - January 21, 2023 Category: Information Technology Source Type: research

Arterial to end-tidal CO2 gradients during isocapnic hyperventilation
AbstractIsocapnic hyperventilation (ICHV) is occasionally used to maintain the end-expired CO2 partial pressure (PETCO2) when the inspired CO2 (PICO2) rises. Whether maintaining PETCO2 with ICHV during an increase of the PICO2 also maintains arterial PCO2 (PaCO2) remains poorly documented. 12 ASA PS I –II subjects undergoing a robot-assisted radical prostatectomy (RARP) (n = 11) or cystectomy (n = 1) under general endotracheal anesthesia with sevoflurane in O2/air (40% inspired O2) were enrolled. PICO2 was sequentially increased from 0 to 0.5, 1.0, 1.5 and 2% by adding CO2 to the inspiratory limb of the circle sy...
Source: Journal of Clinical Monitoring and Computing - January 21, 2023 Category: Information Technology Source Type: research

Is it feasible to measure intra-abdominal pressure using a balloon-tipped rectal catheter? Results of a validation study
AbstractThe gold standard to measure intra-abdominal pressure (IAP) is intra-vesical measurement via the urinary bladder. However, this technique is restricted in ambulatory settings because of the risk of iatrogenic urinary tract infections. Rectal IAP measurements (IAPrect) may overcome these limitations, but requires validation. This validation study compares the IAPrect technique against gold standard intra-vesical IAP measurements (IAPves). IAPrect using an air-filled balloon catheter and IAPves using Foley Manometer Low Volume were measured simultaneously in sedated and ventilated patients. Measurements were performe...
Source: Journal of Clinical Monitoring and Computing - January 21, 2023 Category: Information Technology Source Type: research

Comparison between the Rotational Thromboelastometry (ROTEM) Delta device against the Cartridge-based Thromboelastography 6s and Quantra in a healthy third trimester pregnant cohort
AbstractRotational Thromboelastometry (ROTEM) Delta has been described in several postpartum hemorrhage algorithms, but this device requires pipetting and careful mixing of reagents to initiate the clotting reaction. In contrast, thromboelastography (TEG 6s) and the Quantra devices operate utilizing an automated pre-mixed cartridge that only requires a blood sample to start the clot strength analysis. We compared the correlation between 3 point of care viscoelastic testing (POCVT) devices to laboratory Clauss fibrinogen and platelets, their inter-device correlation, and the total running time difference between Quantra and...
Source: Journal of Clinical Monitoring and Computing - January 21, 2023 Category: Information Technology Source Type: research

Effects of infusion tubing line lengths and syringe sizes on infusion system compliance: an experimental study using a syringe-type infusion pump at low flow rate
In conclusion, the compliance of a syringe pump system increases as the loaded syringe size, or the length of the infusion tubing increases. The occlusion alarm may be much delayed and not useful in highly compliant systems with respect to the potential occlusion of the infusion system, so more attention is required when using a highly compliant infusion system. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - January 17, 2023 Category: Information Technology Source Type: research

Intradural extramedullary tumor location in the axial view affects the alert timing of intraoperative neurophysiologic monitoring
Conclusion: Alert is probably triggered during tumor resection for anterolaterally located tumors. Alerts during tumor resection procedures were more likely to be rescued than other procedures in IDEM tumor surgery. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - January 13, 2023 Category: Information Technology Source Type: research

Feasibility and optimal choice of stimulation parameters for supramaximal stimulation of motor evoked potentials
Conclusion: We recommend using setting 1 when monitoring mTc-MEPs with supramaximal stimulation, after which an individualized ISI optimization can be performed. Moreover, when using supramaximal stimulation, short ISI ’s (i.e. 1ms or 1.5ms) can be the optimal ISI for obtaining the highest mTc-MEP amplitude. (Source: Journal of Clinical Monitoring and Computing)
Source: Journal of Clinical Monitoring and Computing - January 13, 2023 Category: Information Technology Source Type: research