OXYGEN Gas [CLAY COUNTY HOSPITAL DME]
Updated Date: Fri, 04 Oct 2019 00:00:00 EDT (Source: DailyMed Drug Label Updates)
Source: DailyMed Drug Label Updates - October 4, 2019 Category: Drugs & Pharmacology Source Type: alerts
NORTHSIDE HOSPITAL MOTHERS BAG (Alcohol And Sodium Monofluorophosphate) Kit [ASP Global, LLc]
Updated Date: Fri, 20 Sep 2019 00:00:00 EDT (Source: DailyMed Drug Label Updates)
Source: DailyMed Drug Label Updates - September 20, 2019 Category: Drugs & Pharmacology Source Type: alerts
NORTHSIDE HOSPITAL AMENITY KIT (Alcohol And Sodium Monofluorophospate) Kit [ASP Global, LLc]
Updated Date: Wed, 18 Sep 2019 00:00:00 EDT (Source: DailyMed Drug Label Updates)
Source: DailyMed Drug Label Updates - September 18, 2019 Category: Drugs & Pharmacology Source Type: alerts
NORTHSIDE HOSPITAL C-SECTION MOTHERS BAG (Alcohol And Sodium Monofluorophospate) Kit [ASP Global, LLc]
Updated Date: Wed, 18 Sep 2019 00:00:00 EDT (Source: DailyMed Drug Label Updates)
Source: DailyMed Drug Label Updates - September 18, 2019 Category: Drugs & Pharmacology Source Type: alerts
GRACIE SQUARE HOSPITAL AMENITY (Sodium Monofluorophosphate) Kit [ASP Global, LLc]
Updated Date: Tue, 17 Sep 2019 00:00:00 EDT (Source: DailyMed Drug Label Updates)
Source: DailyMed Drug Label Updates - September 17, 2019 Category: Drugs & Pharmacology Source Type: alerts
Stryker Communications - Berchtold Chromophare F528 Surgical Lights - Class 2 Recall
Berchtold Chromophare F528 Surgical Lights. Product Usage: The medical lights are for usage in hospital treatment rooms. They provide localized lighting focused on the patient s body for detecting and treating disease, injury, and disability. The surgical lights may only be used in rooms used for medical purposes that have been equipped in accordance with VDE 0100-710 or IEC 60364-7-10 in accordance with the regulations. (Source: Medical Device Recalls)
Source: Medical Device Recalls - September 13, 2019 Category: Medical Devices Source Type: alerts
Stryker Communications - Berchtold Chromophare F628 Surgical Lights - Class 2 Recall
Berchtold Chromophare F628 Surgical Lights. Product Usage: The medical lights are for usage in hospital treatment rooms. They provide localized lighting focused on the patient s body for detecting and treating disease, injury, and disability. The surgical lights may only be used in rooms used for medical purposes that have been equipped in accordance with VDE 0100-710 or IEC 60364-7-10 in accordance with the regulations. (Source: Medical Device Recalls)
Source: Medical Device Recalls - September 13, 2019 Category: Medical Devices Source Type: alerts
CooperSurgical, Inc. - TransWarmer - Class 2 Recall
TransWarmer Warming Infant Transport Mattress, Model no. 20421 Product Usage: The TransWarmer¿ Warming Infant Transport Mattress is gel-filled, disposable mattress that provides heat for up to two hours when cold stress is a concern. The patented WarmGel heats up to 104 (when starting from 75 ) in 60 seconds or less. The product is sold in boxes of 6 Infant Transport Mattresses per box. The intended use of the product is to provide warmth during infant transport within the hospital or between hospitals. (Source: Medical Device Recalls)
Source: Medical Device Recalls - August 25, 2019 Category: Medical Devices Source Type: alerts
Canadian Hospital Specialties - MEDRX POLYURETHANE FEEDING TUBE - Class 2 Recall
MED-RX POLYURETHANE FEEDING TUBES: a) 5Fr X 16" (40cm), REF 54-1650R b) 6.5Fr X16" (40cm), REF 54-1665R c) 5Fr X 24" (60cm), REF 54-2450R d) 6.5Fr X 24" (60cm), REF 54-2465R e) 8Fr X 24: (60cm), REF 54-2480R f) 8Fr X 36" (91cm), REF 54-3680R (Source: Medical Device Recalls)
Source: Medical Device Recalls - August 16, 2019 Category: Medical Devices Source Type: alerts
Fenwal Inc - VOLUMAT MC AGILIA US - Class 1 Recall
VOLUMAT MC AGILIA US, Infusion Pump, REF Z021135, software versions 1.7 and 1.9a Product Usage: The Volumat MC Agilia is a piece of transportable medical equipment intended to be used in healthcare facilities environment by healthcare trained professionals according to hospital protocols on adults, pediatrics and neonatal human patient to administer via a single channel or mounted on a multiple channels rack accessory: Intermittent or continuous delivery of parenteral fluids (solutions, colloids, parenteral nutrition) and medications (including but limited to diluted drugs, chemotherapy) through clinically accepted IV ro...
Source: Medical Device Recalls - August 13, 2019 Category: Medical Devices Source Type: alerts
GETINGE US SALES LLC - PulsioFlex Monitor - Class 2 Recall
PulsioFlex Monitoring System, Part Number: 6882747, Model Number: PC400 3 R0. Usage: The PulsioFlex Monitoring System is indicated in patients where cardiovascular and circulatory volume status monitoring is necessary. If a patient s biometric data are entered, the PulsioFlex Monitor presents the derived parameters indexed. ¿ -With the PiCCO Module cardiac output is determined both continuously through pulse contour analysis and intermittently through thermodilution technique. Both are used for the determination of other derived parameters. -With the CeVOX oximetry module connected to a compatible oximetry probe, the...
Source: Medical Device Recalls - July 26, 2019 Category: Medical Devices Source Type: alerts
Hamilton Medical AG - Hamilton G5 Ventilator - Class 1 Recall
HAMILTON-G5, with software versions less than or equal to 2.60 The HAMILTON-G5/S1 ventilators are designed for intensive care ventilation of adult and pediatric patients, and optionally infant and neonatal patients. The device is intended for use in the hospital and institutional environment where health care professionals provide patient care. (Source: Medical Device Recalls)
Source: Medical Device Recalls - July 12, 2019 Category: Medical Devices Source Type: alerts
Maquet Cardiovascular, LLC - Class 2 Recall
Maquet Getinge-T 5220 UAB Hospital Accessory Material: 709000426 (Source: Medical Device Recalls)
Source: Medical Device Recalls - June 1, 2019 Category: Medical Devices Source Type: alerts
Maquet Cardiovascular, LLC - Class 2 Recall
Maquet Getinge- BEQ-T 5211 ECC Large Children's Hospital Material: 701064560R01 (Source: Medical Device Recalls)
Source: Medical Device Recalls - June 1, 2019 Category: Medical Devices Source Type: alerts
Baxter Healthcare Corporation - Baxter SIGMA Spectrum Infusion Pump - Class 2 Recall
Baxter SIGMA Spectrum Infusion Pump with Master Drug Library (Version 6), product code 35700BAX - Product Usage: The Baxter SIGMA Spectrum Infusion Pump with Master Drug Library is intended to be used for the controlled administration of fluids. These fluids may include pharmaceutical drugs, blood, blood products and mixture of required patient therapy. The intended routes of administration consist of the following clinically accepted routes: intravenous, arterial, subcutaneous, intrathecal, epidural or irrigation of fluid space. Spectrum Infusion Pump is intended to be used in conjunction with legally marketed intravenous...
Source: Medical Device Recalls - May 3, 2019 Category: Medical Devices Source Type: alerts