A Deep Learning Model with High Standalone Performance for Diagnosis of Unruptured Intracranial Aneurysm
CONCLUSION: The present deep learning model for automated detection of unruptured intracranial aneurysms on TOF MRA achieved the target diagnostic performance comparable to that of human radiologists. With high standalone performance, this model may be useful for accurate and efficient diagnosis of intracranial aneurysm.PMID:34672139 | DOI:10.3349/ymj.2021.62.11.1052
Source: Yonsei Medical Journal - Category: Universities & Medical Training Authors: Bio Joo Hyun Seok Choi Sung Soo Ahn Jihoon Cha So Yeon Won Beomseok Sohn Hwiyoung Kim Kyunghwa Han Hwa Pyung Kim Jong Mun Choi Sang Min Lee Tae Gyu Kim Seung-Koo Lee Source Type: research