Inter-observer and Inter-vendor Variability in Strain Measurements in Patients with Single Right Ventricular Anatomy

AbstractMyocardial strain offers new insights into ventricular performance, There are software packages from several different companies used to ascertain this, and little data is available in patients with single right ventricle (sRV) physiology. We aimed to compare the analysis of two strain software applications using a cohort of patients with sRV for both inter-vendor and inter-observer variability. Echocardiograms from 85 patients with sRV (122 separate studies) were prospectively evaluated. All had Glenn and/or Fontan palliation. Longitudinal 4-chamber (4LS), inflow/outflow (IO), circumferential, and radial strain were assessed using Velocity Vector Imaging (VVI, Seimens, Munich) and Automated Functional Imaging (AFI, General Electric, Boston) software. In a subset of 45 patients (61 separate studies), strain measurements were obtained by two sonographers so a paired “inter-observer” analysis could be performed. A moderate correlation between measurements made by the two systems was observed. Circumferential strain assessment had the highestR value (0.77) with all others havingR values  <  0.6. Both software packages showed modest inter-observer reproducibility for longitudinal and circumferential strain. VVI intraclass correlation coefficients (ICC) for 4LS and average circumferential strain (ACS) were 0.6 and 0.58, compared to 0.68 and 0.59 for AFI. Other than radial strain and V VI IO inferior strain, mean strain differences between AFI and VVI were ≤...
Source: Mammalian Genome - Category: Genetics & Stem Cells Source Type: research