Advanced imaging improves detection of baffle leaks and stenoses after atrial switch compared with transthoracic echocardiography

This study reviews and compares CMR, transesophageal echocardiography (TEE), CCT, cardiac catheterization with angiography and TTE in detection of baffle problems in patients after atrial switch operation. The medical records of patients who had at least one imaging study performed after atrial switch operation at our center from 2010 to 2020 were retrospectively reviewed. Results are reported as descriptive statistics for demographics and imaging findings. The principal outcome measure was detection of baffle leak and/or baffle stenosis. Fifty-seven patients had at least one cardiac imaging study after atrial switch operation (36 Senning and 21 Mustard operations) during the study period. Nearly 33% (19/57) had baffle complications of stenosis and/or baffle leaks identified. All 57 patients had TTE performed but baffle problems were noted by TTE in only 8 (14%) patients (7 baffle stenosis and 1 baffle leak). Of the 49 patients without known baffle problems by TTE, 24 had advanced imaging (TEE/CCT/CMR/angiography). Advanced imaging identified baffle problems in nearly half (11/24, 46%) of them (7 baffle leaks and 4 baffle stenosis). Baffle problems were present in (8/23) patients with transvenous cardiac devices. Baffle complications are common after atrial switch operations and in our study occur in 1/3rd of the patients. However, TTE is not sensitive enough to recognize these complications. Advanced imaging for detection of baffle complications should be considered in all p...
Source: The International Journal of Cardiovascular Imaging - Category: Radiology Source Type: research