Outcomes of robotically assisted laparoscopic lateral suspension (RALLS) with mesh for anterior and apical prolapse

The objective of our study was to evaluate outcomes of robotically assisted laparoscopic lateral suspension (RALLS) with mesh for anterior and apical pelvic organ prolapse (POP). From March 2012 to January 2018, 59 consecutive patients underwent RALLS using titanized polypropylene mesh. Between August 2017 and September 2019, all patients were contacted to assess outcome. We performed a clinical exam and asked them to complete the patient global impression of improvement (PGI-I) questionnaire. Fifty-four patients (91.5%) were available for follow-up. Mean age was 58.5  years (28.8–79.8). There were no perioperative complications. The mean follow-up was 33.6 months (11.2–74.1).The objective cure rate (no prolapse beyond hymen) and the subjective cure rate (PGI-I ≤ 2) were 83.3% and 77.2%, respectively. Five women (9.3%) were reoperated for POP recurren ce. There was no erosion. Of the 20 women complaining of stress urinary incontinence (SUI) preoperatively, 12 (60%) were cured without any additional SUI procedure. Only two women (10%) required TVT for persistent grade 2 SUI. Two women (5.9%) developed de novo SUI, but none of them required an operation. RALLS repair for POP with mesh is safe and effective and may represent an alternative to sacral colpopexy/hysteropexy.
Source: Journal of Robotic Surgery - Category: Surgery Source Type: research