Surgical Technique for Harvesting ECRL and ECRB Concurrently as Upper Extremity Tendon Autograft

In this report, we describe an easily reproducible, quick, and low-morbidity technique using both the wrist extensors—extensor carpi radialis longus and extensor carpi radialis brevis, from near their distal attachments to their musculotendinous junctions proximally—as a source of tendon autograft for a variety of applications.
Source: Techniques in Hand and Upper Extremity Surgery - Category: Surgery Tags: Techniques Source Type: research
More News: Bone Graft | Surgery