Influence of Pulse Waveform and Frequency on Evoked Torque, Stimulation Efficiency, and Discomfort in Healthy Subjects

Conclusions The higher stimulation efficiency of symmetrical pulses suggests that this waveform would be preferred to asymmetrical pulses in clinical practice. Stimulation frequencies between 60 and 100 Hz can be used interchangeably because of similar efficiency and discomfort.
Source: American Journal of Physical Medicine and Rehabilitation - Category: Rehabilitation Tags: Original Research Articles Source Type: research