Incidence of gastric insufflation at high compared with low laryngeal mask cuff pressure: A randomised controlled cross-over trial

BACKGROUND The success of ventilation with a laryngeal mask depends crucially on the seal between the mask and the periglottic tissue. Increasing the laryngeal mask's cuff volume is known to reduce oral air leakage but may lead to gastric insufflation. OBJECTIVE We hypothesised that a lower cuff pressure would result in less gastric insufflation. We sought to compare gastric insufflation with laryngeal mask cuff pressures of 20 cmH2O (CP20) and 60 cmH2O (CP60) during increasing peak airway pressures in a randomised controlled double-blind cross-over study. We also evaluated the incidence of gastric insufflation at the recommended peak airway pressure of 20 cmH2O or less and during both intermittent positive airway pressure and continuous positive airway pressure. METHODS After obtaining ethics approval and written informed consent, 184 patients ventilated via laryngeal mask received a stepwise increase in peak airway pressure from 15 to 30 cmH2O with CP20 and CP60 in turn. Gastric insufflation was determined via real-time ultrasound and measurement of the cross-sectional area of the gastric antrum. The primary endpoint was the incidence of gastric insufflation at the different laryngeal mask cuff pressures. RESULTS Data from 164 patients were analysed. Gastric insufflation occurred less frequently at CP20 compared with CP60 (P 
Source: European Journal of Anaesthesiology - Category: Anesthesiology Tags: Airway Source Type: research