Epidural Hemostasis by Autogenous Fat Graft in Minimally Invasive Surgery for Lumbar Spinal Stenosis: In Vivo Experimental Study.

CONCLUSIONS: The autologous fat graft ensured sufficient and safe epidural hemostasis without serious adverse events in minimally invasive spinal surgery, and is preferable as autologous tissue is easily and quickly harvested. The surgeon feels safe with this technique and does not need external hemostatic agents. PMID: 33232714 [PubMed - as supplied by publisher]
Source: Neuro-Chirurgie - Category: Neurosurgery Authors: Tags: Neurochirurgie Source Type: research