Incidence of pacing induced cardiomyopathy in pacemaker dependent patients is lower with leadless pacemakers compared to transvenous pacemakers
ConclusionIncidence of PICM is significantly lower with LP compared to TVP in pacemaker dependent patients. Age and TVP as pacing modality were predictors for PICM.This article is protected by copyright. All rights reserved.
Source: Journal of Cardiovascular Electrophysiology - Category: Cardiology Authors: Reynaldo Sanchez,
Anish Nadkarni,
Benjamin Buck,
Georges Daoud,
Tanner Koppert,
Toshimasa Okabe,
Mahmoud Houmsse,
Raul Weiss,
Ralph Augostini,
John D. Hummel,
Steven Kalbfleisch,
Emile G. Daoud,
Muhammad R. Afzal Tags: ORIGINAL ‐ DEVICES Source Type: research