Transesophageal echocardiography in swine: evaluation of left and right ventricular structure, function and myocardial work

This study aimed to determine standard left (LV) and right ventricular (RV) transesophageal echocardiographic (TEE) measurements in swine. Additionally, global myocardial work index (GWI) was estimated using pressure-strain loops (PSL). A comprehensive TEE examination was conducted in ten anesthetized, intubated and mechanically ventilated healthy female German landrace swine, weighing 44 to 57 kg. For GWI calculation, we performed LV and RV segmental strain analysis and used invasively measured LV and RV pressure to obtain PSL. The GWI and further myocardial work indices were calculated from the area of the PSL using commercially available software. Furthermore, hemodynamic measurements were obtained using indwelling catheters. We obtained complete standardized baseline values for left and right ventricular dimensions and function. Biplane LV ejection fraction was 63 ± 7 % and the LV end-diastolic volume was 70.5 ± 5.9 ml. Tissue Doppler estimated peak tricuspid annular systolic velocity was 13.1 ± 1.8 cm/s. The Doppler estimated LV and RV stroke volume index were 75.6 ± 7.2 ml/m2 and 76.7 ± 7.8 ml/m2 respectively. Pulsed wave Doppler derived cardiac output correlated well with cardiac output estimated using the thermodilution method (7.0 ± 1.2 l/min vs. 7.0 ± 1.1 l/min, r = 0.812, p = 0.004). The LV global longitudinal strain was -21.3 ± 3.9 % and the RV global longitudinal strain was -15.4 ± 2.5 %. LV GWI was 1885(1281–2121) mmHg*% and 297 ± 62 mmHg*% for the R...