Portable Gait Lab: Tracking Relative Distances of Feet and CoM Using Three IMUs

In this study, we track the relative distances using the assumptions of the Centroidal Moment Pivot (CMP) theory. An Extended Kalman filter approach was used to fuse information from different sources: strapdown inertial navigation, commonly used constraints such as zero velocity updates, and relative segment distances from the CMP assumption; to eventually track relative feet and CoM positions. These estimates were expressed in a reference frame defined by the heading of each step. The validity of this approach was tested on variable gait. The step lengths and step widths were estimated with an average absolute error of 4.6±1.5 cm and 3.8±1.5 cm respectively when compared against the reference VICON©. Additionally, we validated the relative distances of the feet and the CoM, and further, show that the approach proves useful in identifying asymmetric gait patterns. We conclude that a three IMU approach is feasible as a portable gait lab for ambulatory measurement of foot and CoM positions in daily life.
Source: IEE Transactions on Neural Systems and Rehabilitation Engineering - Category: Neuroscience Source Type: research