Percutaneous-assisted vs mini-laparoscopic hysterectomy: comparison of ultra-minimally invasive approaches

AbstractTo assess the feasibility and the safety of the ultra-minimally invasive (U-MIS) approaches in gynecology, we compared our experience in percutaneous assisted hysterectomy (PSS-H) with a series of 3  mm mini-laparoscopy hysterectomy (m-LPS-H). 126 patients affected by benign and malignant gynecological conditions were considered eligible for minimally invasive hysterectomy: 80 patients received PSS approach and 46  m-LPS approach. For both groups, we evaluated intra and perioperative outcomes, post-operative pain and cosmetic outcomes. The baseline characteristics were comparable between the two study groups. As well, no differences were reported in the clinical indications for hysterectomy, principally fibr oids/adenomyosis, endometrial hyperplasia and early stage endometrial cancer. The median operative time was 88.5 (40–190) minutes for PSS-H group and 95.0 (42–231) minutes in m-LPS-H group (p = 0.131). No differences were detected in median estimated blood loss (p = 0.104) as well, in the uterine manipulator usage (p = 0.127) between the two different surgical approaches. Only 1 (2.2%) conversion to standard laparoscopy occurred in m-LPS-H group (p = 0.691). One intra-operative complication was recorded 1 (1.3%) in the PSS-H group (p = 0.367). The post-operative early complication was recorded in five cases of PSS-H group (p = 0.158), none for m-LPS-H procedures. The results in post-operative pain detection was statistically significa...
Source: Updates in Surgery - Category: Surgery Source Type: research