A protective hinge wire, intersecting the osteotomy plane, can reduce the occurrence of perioperative hinge fractures in medial opening wedge osteotomy

ConclusionThis study demonstrated that during OWHTO, positioning a K-wire intersecting the cutting plane at the theoretical lateral hinge location reduced the number of intraoperative lateral hinge fractures.Level of evidenceIII retrospective case –control study.
Source: Knee Surgery, Sports Traumatology, Arthroscopy - Category: Orthopaedics Source Type: research