Strain analysis using feature tracking cardiac magnetic resonance (FT-CMR) in the assessment of myocardial viability in chronic ischemic patients

AbstractThe purpose of this study is to  test the capability of a commercially available feature tracking-cardiac magnetic resonance (FT-CMR) strain analysis software module in differentiating between viable and non-viable myocardium in chronic ischemic patients. Thirty chronic ischemic patients and 10 healthy volunteers were enrolled. C ine images were used for peak circumferential and radial strains quantification using dedicated FT-CMR software. Global strain was compared between patients and controls. In patients, segmental strain was compared in viable and non-viable myocardium determined by late gadolinium enhancement (LGE); a nd in segments with wall abnormalities. Among 480 myocardial segments analyzed in patients, 76 segments were non-viable on LGE. The mean left ventricular ejection fraction (LVEF) of the patients (87% males, mean age 55 ± 12 years) was 40 ± 12% vs. 61 ± 5% for the controls (80% males, mean age 39 ± 11 years). Peak global circumferential strain (GCS) and global radial strain (GRS) were significantly impaired in patients compared to controls (−13.89 ± 4.12% vs. −19.84 ± 1.47%), p <  0.001 and (23.11 ± 6.59% vs. 31.72 ± 5.52%), p = 0.001. Segmental circumferential strain (SCS) and segmental radial strain (SRS) were significantly impaired in non-viable compared to viable segments (-9.47 ± 7.26% vs. -14.72 ± 7.5%), p <  0.001 and (15.67 ± 12.11% vs. 24.51 ± 16.22%), pâ€...
Source: The International Journal of Cardiovascular Imaging - Category: Radiology Source Type: research