ConclusionEndoscopy reports frequently do not include the use of a grading system for esophagitis or the Prague system for CLE. This hampers the assessment of change with therapy or over time. The size of a hiatal hernia was typically reported in a subjective fashion and only infrequently was the type specified. Lack of clarity about the presence of a paraesophageal hernia can impede evaluation of acute symptoms. In patients with Barrett ’s esophagus a standard biopsy protocol was infrequently reported to be used. These findings raise concern about the quality of upper endoscopy, both in the performance of the procedure and the documentation of findings. A consistent reporting system is recommended for routine use with upper endos copy.