. Clin Nephrol. 2020 Jun 26;: Authors: Ichigi M, Nakatani S, Murakami M, Harada Y, Utsumi S, Ogata M, Maehara Y, Ikeda H, Shimada H, Fukunaga M, Narita Y, Saruwatari J, Kondo Y, Ishitsuka Y, Irie T, Kadowaki D, Hirata S Abstract Serum creatinine (SCr) levels depend on muscle mass and are therefore elevated in people with high muscle mass, potentially leading to underestimation of kidney function in this population. Although recent therapeutic guidelines have shown measurement of serum cystatin C (ScysC) to be useful, this method has not been validated in people with high muscle mass. We conducted this study to investigate methods for more accurately estimating kidney function in people with high muscle mass. Linear regression analysis was used to assess the correlation of endogenous creatinine clearance (24-hour CLcr) and 24-hour CLcr × 0.715 (i.e., modified glomerular filtration rate (GFR)); with estimated kidney function from SCr and ScysC in 15 healthy young adult men with high muscle mass. A significant but weak positive correlation was observed between 24-hour CLcr and estimated CLcr by the Cockcroft and Gault formula (CG CLcr; R2 = 0.371, p = 0.016). The estimated GFR calculated from ScysC (eGFRcys) was significantly higher than CLcr × 0.715, but the two were not correlated (R2 = 0.125, p = 0.197). However, when ...