Dosimetric and planning efficiency comparison for lung SBRT: CyberKnife vs VMAT vs knowledge-based VMAT

This is the first study that compared treatment plan quality and planning efficiency for lung stereotactic body radiation therapy (SBRT) using CyberKnife (CK) Multiplan vs Varian Eclipse treatment planning systems, including volumetric modulated arc therapy (VMAT) and knowledge-based VMAT (KBP-VMAT). Thirteen lung SBRT patients treated with 50 to 55 Gy in 3 or 5 fractions were retrospectively included in this study. CK plans created with Multiplan V. 4.6.1 using 2 fixed circular cones were previously approved used for treatment.
Source: Medical Dosimetry - Category: Radiology Authors: Source Type: research