Closing peritoneal tear during laparoscopic inguinal hernia repair: simple and effective technique

ConclusionsPeritoneal tears occurring inadvertently during Laparoscopic TAPP/TEP procedure for repair inguinal hernia can be effectively sealed with simple bipolar diathermy