Presence of other rare earth metals in gadolinium-based contrast agents.

In this study, the presence of other RE in GBCA formulations was investigated. Different lots of Magnevist®, Viewgam®, OptiMARK®, Omniscan®, Dotarem®, and Gadovist® were analyzed. Inductively-coupled plasma mass spectrometry and atomic absorption spectrometry were used for RE determination. Procedure optimization included sample decomposition and method validation for element determination. The results showed that Sc, Y, La, Ce, Pr, Nd, Eu, Tb, Tm, Dy, Ho, and Er were present in the 22 samples analyzed. Terbium, Thulium, Europium, and Lanthanum were, on average, found in the highest amounts, which were 0.42 mg/L, 0.17 mg/L, 0.17 mg/L, and 0.16 mg/L, respectively. These results could be attributed to the similarity among Europium, Gadolinium, and Terbium. They are in sequence in the periodic table and therefore present very close ionic radii, restricting their separation. Considering the sum of all RE, Viewgam® was the most contaminated formulation (mean of 2.16 mg/L) and Magnevist® the least (mean of 0.64 mg/L). Although the RE are chemically similar, the other RE do not perform as Gd as a contrast agent; therefore, their presence in formulations may be a matter of concern. PMID: 32456901 [PubMed - in process]
Source: Talanta - Category: Chemistry Authors: Tags: Talanta Source Type: research