Real-time monitoring of multi-layered film coating processes using Raman spectroscopy.

In conclusion, a real-time monitoring of a multi-layered coating process was achieved, PLS-regression was found to be superior to MCR-ALS and smoothing by the implementation of a moving average enhanced the predictability. PMID: 32445967 [PubMed - as supplied by publisher]
Source: European Journal of Pharmaceutics and Biopharmaceutics - Category: Drugs & Pharmacology Authors: Tags: Eur J Pharm Biopharm Source Type: research