Target miss using PTV-based IMRT compared to robust optimization via coverage probability concept in prostate cancer.

Conclusions: Probabilistic dose-escalated IMRT was feasible in this prospective study. Comparison of the CovP-concept with PTV-based IMRT revealed superiority with regard to target-coverage and sparing of OARs. The CovP-concept implements a robust plan optimization strategy for organ deformation and motions and could, therefore, serve as a less demanding compromise on the way to adaptive IGRT avoiding daily time-consuming re-planning. SUMMARYWe evaluated the robustness of coverage probability (CovP)-based IMRT plans within a prospective study for prostate cancer radiotherapy. The treatment plans were compared with newly calculated conventional PTV-based IMRT plans. We were able to show that CovP led to a clearly more robust target coverage by avoiding hot spots at OARs compared to conventional PTV-based IMRT. In addition, negative consequences of an inflated PTV can be ameliorated by a more relaxed CovP-based dose prescription. PMID: 32436467 [PubMed - as supplied by publisher]
Source: Acta Oncologica - Category: Cancer & Oncology Authors: Tags: Acta Oncol Source Type: research