Enhancing Communication for People in Late-Stage ALS Using an fNIRS-Based BCI System

In this study, we developed a new fNIRS-based BCI system in concert with a single-trial Visuo-Mental (VM) paradigm to investigate the feasibility of enhanced communication for ALS patients, particularly those in the later stages of the disease. Methods: In the first part of the study, we recorded data from six ALS patients using our proposed protocol (fNIRS-VM) and compared the results with the conventional electroencephalography (EEG)-based multi-trial P3Speller (P3S). In the second part, we recorded longitudinal data from one patient in the late locked-in state (LIS) who had fully lost eye-gaze control. Using statistical parametric mapping (SPM) and correlation analysis, the optimal channels and hemodynamic features were selected and used in linear discriminant analysis (LDA). Results: Over all the subjects, we obtained an average accuracy of 81.3%±5.7% within comparatively short times (< 4 sec) in the fNIRS-VM protocol relative to an average accuracy of 74.0%±8.9% in the P3S, though not competitive in patients with no substantial visual problems. Our longitudinal analysis showed substantially superior accuracy using the proposed fNIRS-VM protocol (73.2%±2.0%) over the P3S (61.8%±1.5%). Significance: Our findings indicate the potential efficacy of our proposed system for communication and co- trol for late-stage ALS patients.