Human lumbar spinal column injury criteria from vertical loading at the base: Applications to military environments.

The objective of this study was to determine force-based lumbar spine injury criteria due to vertical impact using Post Mortem Human Surrogate (PMHS) experiments. Mounted personnel in military vehicles sustain loads from the pelvis in combat events such as underbody blast loadings. Forty-three post mortem human subject thoracolumbar spinal columns were obtained, screened for pre-existing trauma, bone mineral densities (BMDs) were determined, pre-test radiological images were taken, fixed at the ends in polymethylmethacrylate, load cells were attached to the ends of the fixation, positioned on custom vertical accelerator device based on a military-seating posture, and impacted at the base. Posttest images were obtained, and gross dissection was done to confirm injuries, classified into single and multilevel groups, groups A and B. Axial and resultant forces at the thoracolumbar (proximal) and lumbosacral (distal) joints were used as response variables to develop lumbar spine injury risk curves using parametric survival analysis. The Brier score metric was used to rank the variables. Age, BMD, column length, and vertebral body and intervertebral disc areas were used as covariates. The optimal metric describing the underlying response to injury was the distal resultant force for group A and proximal axial force for group B specimens. Force-BMD for group A and force-body area for group B were the best combinations. The IRCs with ±95% confidence intervals and quality of risk curv...
Source: Journal of the Mechanical Behavior of Biomedical Materials - Category: Materials Science Authors: Tags: J Mech Behav Biomed Mater Source Type: research