A numerical study on the influence of different tunnel lining insulation materials in a road tunnel fire

This study shows tunnel protected with calcium silicate board results in higher temperature and heat fluxes compare to non-protected tunnel and tunnel protected with magnesium oxides/Cement based spray. This indicates that passive fire protection system can alter the thermal conditions inside the tunnel in case of fire.
Source: Materials Today: Proceedings - Category: Materials Science Source Type: research