In Vitro Characterization of a Novel Type of Radiopaque Doxorubicin-Loaded Microsphere.

CONCLUSION: V-100 is a promising novel type of radiopaque doxorubicin-loaded microsphere. Compared with the controls, V-100 shows good inherent radiopacity without adverse imaging artifacts and with comparable doxorubicin loading efficacy. Further advantages of V-100 include narrow-sized distribution and excellent suspension, rheology, and stability features. PMID: 31965224 [PubMed - as supplied by publisher]
Source: Methods of Information in Medicine - Category: Information Technology Authors: Tags: Cardiovasc Intervent Radiol Source Type: research