Size distribution and concentration of fungal aerosol in animal premises of a zoological garden

This study aimed to assess the levels of fungal aerosol in animal premises (tapirs, giraffes, pygmy hippos, monkeys, meerkats, pheasants, ostriches, exotarium) of the Krak ów Zoo. The bioaerosol samples were collected using a six-stage Andersen impactor to assess the concentrations and size distribution of airborne fungi. Particulate matter (PM10, PM4, PM2.5 and PM1) concentration was assessed using DustTrak Aerosol Monitor. PM concentrations were relatively low (0.048 –0.204 mg/m3) and did not exceed the limit values for occupational exposure. Also, the levels of fungal aerosol in almost all cases did not exceed the limit values. The smallest concentration of the total fungal aerosol was observed in the rooms for hippos (approx. 970  CFU/m3) while the highest —in exotarium (16,800 CFU/m3). The share of respirable fraction of bioaerosol was quite high —from 62.6% in monkey houses to 89.2% in exotarium. Having in mind that bioaerosol-forming fungi may contain allergenic species, attention should be paid to thorough cleaning of animals and their premises, and maintaining appropriate levels of microclimatic parameters in the rooms.
Source: Aerobiologia - Category: Environmental Health Source Type: research