Effect of interfacial drag force model on code prediction for upward adiabatic two-phase bubbly flow in vertical channels

AbstractAccurate modeling of the interfacial drag force is one of the keys to predicting thermo-fluid parameters using one-dimensional nuclear thermal-hydraulic system analysis code architected through the two-fluid model. The interfacial drag force appears in the interfacial momentum transfer term and governs the velocity slip or the relative velocity between gas and liquid phases. The most straightforward method to model the interfacial drag force is to model the force through the drag law (drag law approach). A drag coefficient and interfacial area concentration should be given to close the interfacial drag force model. Among them, the modeling of the interfacial area concentration has been one of the weakest links in the interfacial drag force modeling due to the lack of reliable data covering a wide test condition including prototypic nuclear reactor conditions and lack of physically sound interfacial area model. To avoid a considerable uncertainty in the prediction of the interfacial area concentration, Andersen and Chu (1982) proposed the interfacial drag force model using the drift-flux parameters (Andersen approach). The Andersen approach is practical for the simulation of a slow transient flow and a steady flow. Major system analysis codes such as USNRC TRACE have adopted the Andersen approach in the interfacial drag force modeling. Some attempts to improve the code performance have been considered using the drag law approach with the interfacial area transport equa...
Source: European Journal of Applied Physiology - Category: Physiology Source Type: research
More News: Physiology | Study