Biologic and Technical Complications of Implant-Supported Immediately Loaded Fixed Full-Arch Prostheses: An Evaluation of Up to 6 Years.

CONCLUSION: Within this treatment concept, biologic and technical complications may occur over time. However, the vast majority of complications (99.0%) do not affect the overall prosthesis survival. Technical complications are assumed to occur significantly more often than biologic complications. It is suggested that not only stress and material fatigue but also function is a matter concerning this treatment option and, thus, may be a factor related to complication rates. PMID: 31711089 [PubMed - in process]
Source: International Journal of Oral and Maxillofacial Implants - Category: ENT & OMF Tags: Int J Oral Maxillofac Implants Source Type: research