Assessing lead-contaminated drinking water in a large academic institution: a case study.

This study examined lead concentrations in drinking water at a large university, focusing on variability in first-draw samples and variability with dispensed volume. Over 350 sources were sampled twice by independent groups, and while 78% of these samples were within 2.5 μg/L, almost 10% differed by >10 μg/L. In both sampling events, approximately 50% of sources had lead concentrations >1 μg/L, 6% were >15 μg/L, and 30% were between 1 and 15 μg/L. The highest lead concentration detected was 400 μg/L, with five sources >100 μg/L. Nine sources were sampled more intensively and six had first-draw sample ranges >5 μg/L. Lead concentration versus dispensed volume profiles indicated that while most sources had decreasing lead concentrations after the first draw, others had maximum lead concentrations at higher dispensed volumes. The variability observed suggests that assessments using only one or two samples per source may not identify all sources with elevated lead concentrations, and management strategies should account for this possibility. PMID: 31638024 [PubMed - in process]
Source: Journal of Water and Health - Category: Environmental Health Tags: J Water Health Source Type: research