Performance analysis of grafted poly (2-methacryloyloxyethyl phosphorylcholine) on additively manufactured titanium substrate for hip implant applications.

This study focuses on optimising monomer concentration to achieve the best physical, thermal and mechanical properties of the grafted additively manufactured titanium (Ti6Al4V) implants. Three different concentration of monomers, 0.4 M, 0.6 M and 0.8 M, were investigated, and grafted implants were characterised. The results from thermal analysis confirmed that the PMPC polymer is thermally stable for implant applications regardless of the monomer concentrations. A significant reduction in Young's modulus of polymer grafted samples (33.2-42.9%), in comparison with untreated Ti6Al4V samples and consequent improvement of wear resistance and elasticity behaviour, proved the potentiality of polymer films for implant applications. In summary, polymer grafted implant prepared with 0.6 M monomer concentration showed the optimal thermal, physical and wear resistance properties. PMID: 31487620 [PubMed - as supplied by publisher]
Source: Journal of the Mechanical Behavior of Biomedical Materials - Category: Materials Science Authors: Tags: J Mech Behav Biomed Mater Source Type: research