Transcatheter Aortic Valve Implantation in Patients With Pre-Existing Mechanical Mitral Valve Prostheses.

CONCLUSION: TAVI in patients with mechanical MVR is challenging and requires careful preparation and choice of TAVI device. Repositionable and retrievable devices seem to be a safer option. PMID: 31478891 [PubMed - in process]
Source: The Journal of Invasive Cardiology - Category: Cardiology Tags: J Invasive Cardiol Source Type: research