Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience.

Modeling Elekta VersaHD using the Varian Eclipse treatment planning system for photon beams: A single-institution experience. J Appl Clin Med Phys. 2019 Aug 30;: Authors: Zhang Y, Le AH, Tian Z, Iqbal Z, Chiu T, Gu X, Pugachev A, Reynolds R, Park YK, Lin MH, Stojadinovic S Abstract The aim of this study was to report a single-institution experience and commissioning data for Elekta VersaHD linear accelerators (LINACs) for photon beams in the Eclipse treatment planning system (TPS). Two VersaHD LINACs equipped with 160-leaf collimators were commissioned. For each energy, the percent-depth-dose (PDD) curves, beam profiles, output factors, leaf transmission factors and dosimetric leaf gaps (DLGs) were acquired in accordance with the AAPM task group reports No. 45 and No. 106 and the vendor-supplied documents. The measured data were imported into Eclipse TPS to build a VersaHD beam model. The model was validated by creating treatment plans spanning over the full-spectrum of treatment sites and techniques used in our clinic. The quality assurance measurements were performed using MatriXX, ionization chamber, and radiochromic film. The DLG values were iteratively adjusted to optimize the agreement between planned and measured doses. Mobius, an independent LINAC logfile-based quality assurance tool, was also commissioned both for routine intensity-modulated radiation therapy (IMRT) QA and as a secondary check for the Eclipse VersaHD model. The Eclipse-generated...
Source: Journal of Applied Clinical Medical Physics - Category: Physics Authors: Tags: J Appl Clin Med Phys Source Type: research

Related Links:

Publication date: January 2020Source: Radiation Physics and Chemistry, Volume 166Author(s): Fang-Yu Liu, Zhi-Wei Dong, Hui-Bin Yang, Hong-Yun ShiAbstractEven with advanced inverse intensity modulated radiation therapy (IMRT) technique, the optimization of treatment plans remains a time-consuming task and the outcome is highly influenced by the experience of the planner and time pressure. Automated treatment planning is a current hot topic and new frontier in radiotherapy, which is expected to minimize the above problems. The quality and efficacy of the IMRT plans generated by the Auto-Planning module of the Pinnacle3 treat...
Source: Radiation Physics and Chemistry - Category: Physics Source Type: research
ConclusionThis survey was an informative trial to understand the verification status of patient-specific IMRT QA measurements for prostate cancer. In most institutions, the point dose measurement and dose distribution differences met the desired criteria.
Source: Reports of Practical Oncology and Radiotherapy - Category: Cancer & Oncology Source Type: research
Conclusions: We describe here the first report of a potential abscopal effect in meningioma, summarize the limited literature on the topic of abscopal effects in cancer, and detail the existing hypothesis on how this phenomenon may occur and possibly relate to the development of future treatments for patients with metastatic disease.
Source: Frontiers in Oncology - Category: Cancer & Oncology Source Type: research
ConclusionUsing robust optimization for skin flash in breast IMRT planning is feasible. Further investigation is warranted to confirm the clinical effectiveness of this novel approach.
Source: Practical Radiation Oncology - Category: Cancer & Oncology Source Type: research
Conditions:   Oropharynx Cancer;   Oropharynx Squamous Cell Carcinoma;   Carcinoma, Squamous Cell;   Carcinoma;   Oropharyngeal Neoplasms;   Neoplasms, Squamous Cell;   Neoplasms, Glandular and Epithelial;   Neoplasms by Histologic Type;   Pharyngeal Neoplasms Malignant and Unspecif ied;   Otorhinolaryngologic Neoplasms;   Head and Neck Neoplasms;   Neoplasms by Site;   Otorhinolaryngologic Diseases;   Pharyngeal Diseases...
Source: ClinicalTrials.gov - Category: Research Source Type: clinical trials
Older patients undergoing radiation therapy (RT) for pelvic malignancies are at increased risk for pelvic fracture, which is associated with significant morbidity and mortality. RT techniques such as brachytherapy or intensity modulated RT (IMRT) allow for more conformal dose distributions, but it is not known whether the risk for pelvic fracture varies by RT modality.
Source: International Journal of Radiation Oncology * Biology * Physics - Category: Radiology Authors: Source Type: research
Conclusion: IMRT-based CCRT resulted in higher survival rates in patients with advanced clinical stages of TESCC (i.e., IIIA–IIIC), namely, clinical T3, clinical T4, or lymph node involvement.
Source: Cancers - Category: Cancer & Oncology Authors: Tags: Article Source Type: research
This Viewpoint discusses details of the Radiation Oncology Model, a 90-day episode-based alternative payment model proposed by the Centers for Medicare&Medicaid Services (CMS) intended to reduce inappropriate overuse of proton beam therapy, intensity-modulated radiation therapy (IMRT), and other expensive radiation oncology services.
Source: JAMA - Journal of the American Medical Association - Category: General Medicine Source Type: research
era S Abstract Adjuvant radiotherapy is a key treatment in early-stage breast cancer. The meta-analysis by the Early Breast Cancer Trialist's Collaborative Group (EBCTCG) has demonstrated a decreased risk of locoregional relapse and death after whole-breast radiotherapy. Prophylactic lymph nodes irradiation in breast cancer has also proven to be beneficial in several therapeutic trials. At a time when three-dimensional conformal radiotherapy has become the standard procedure and with the development of intensity-modulated radiation therapy, defining nodal volumes is essential and practices should be harmonized to ...
Source: Cancer Radiotherapie - Category: Cancer & Oncology Authors: Tags: Cancer Radiother Source Type: research
Abstract The incidence of brain metastases is increasing and various treatment modalities exist for brain metastases. The aim of this study was to investigate the dosimetric quality and delivery efficiency of robotic radiosurgery (CyberKnife) for multiple brain metastases compared with C-arm linear accelerator (linac) based plans. C-arm linac based plans included intensity-modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT) and non-coplanar VMAT with 1, 3 and 5 non-coplanar arcs, respectively (NC1, NC3 and NC5). For 20 patients, six plans with a prescription dose of 30 Gy in three frac...
Source: Journal of Applied Clinical Medical Physics - Category: Physics Authors: Tags: J Appl Clin Med Phys Source Type: research
More News: Intensity-Modulated Radiation Therapy | Physics | Radiation Therapy | Study