Exercise Interventions in Patients With Implantable Cardioverter-Defibrillators and Cardiac Resynchronization Therapy: A SYSTEMATIC REVIEW AND META-ANALYSIS

Purpose: Physical activity improves outcomes across a broad spectrum of cardiovascular disease. The safety and effectiveness of exercise-based interventions in patients with implantable cardioverter-defibrillators (ICDs) including cardiac resynchronization therapy defibrillators (CRT-Ds) remain poorly understood. Methods: We identified clinical studies using the following search terms: “implantable cardioverter-defibrillators”; “ICD”; “cardiac resynchronization therapy”; “CRT”; and any one of the following: “activity”; “exercise”; “training”; or “rehabilitation”; from January 1, 2000 to October 1, 2015. Eligible studies were evaluated for design and clinical endpoints. Results: A total of 16 studies were included: 8 randomized controlled trials, 5 single-arm trials, 2 observational cohort trials, and 1 randomized crossover trial. A total of 2547 patients were included (intervention groups = 1215 patients, control groups = 1332 patients). Exercise interventions varied widely in character, duration (median 84 d, range: 23-168 d), and follow-up time (median 109 d, range: 23 d to 48 mo). Exercise performance measures were the most common primary endpoints (87.5%), with most studies (81%) demonstrating significant improvement. Implantable cardioverter-defibrillator shocks were uncommon during active exercise intervention, with 6 shocks in 635 patients (0.9%). Implantable cardioverter-defibrillator shocks in follow-up were less common in pati...
Source: Journal of Cardiopulmonary Rehabilitation - Category: Rehabilitation Tags: Scientific Review Source Type: research