The use of self-gripping mesh with anterior component separation technique in incisional hernia repair: A case series

ConclusionThe use of self-gripping mesh with ACS can be performed without increasing the operative time or causing short-term surgical complications. This technique may be recommended for large IH because of its simplicity and secure abdominal reinforcement provided.
Source: International Journal of Surgery Case Reports - Category: Surgery Source Type: research

Related Links:

ConclusionThe outcomes of recurrent incisional hernia repair were significantly associated with potential influencing factors, which are very similar to the factors seen in primary incisional hernia repair. The impact of the primary incisional hernia repair technique, namely laparoscopic IPOM versus open mesh techniques, on the outcome of recurrent incisional hernia repair seems less pronounced than anticipated.
Source: Hernia - Category: Sports Medicine Source Type: research
ConclusionThe Nyhus-inspired robotic iliopubic tract (r-IPT) repair is an MIS approach to provide a non-mesh repair in inguinal hernia. The repair is safe with acceptable preliminary outcomes in low-risk patients. We propose the r-IPT repair to be a MIS option for non-mesh inguinal hernia repair in low-risk patients.
Source: Hernia - Category: Sports Medicine Source Type: research
Objective: Impact of inguinal hernia defect size as stratified by the European Hernia Society (EHS) classification I to III on the rate of chronic postoperative inguinal pain (CPIP). Background: CPIP is the most important complication after inguinal hernia repair. The impact of hernia defect size according to the EHS classification on CPIP is unknown. Methods: In total, 57,999 male patients from the Herniamed registry undergoing primary unilateral inguinal hernia repair including a 1-year follow-up were selected between September 1, 2009 and November 30, 2016. Using multivariable analysis, the impact of EHS inguina...
Source: Annals of Surgery - Category: Surgery Tags: ORIGINAL ARTICLES Source Type: research
Conclusions: Lack of fixation in TEP-IHR does not increase the risk of hernia recurrence, and its presence does not significantly worsen the treatment results; especially it does not increase the incidence of chronic pain. PMID: 32117479 [PubMed]
Source: Videosurgery and Other Miniinvasive Techniques - Category: Surgery Tags: Wideochir Inne Tech Maloinwazyjne Source Type: research
AbstractIntroductionIn an Expert Consensus guided by systematic review, the panel agreed that for open elective incisional hernia repair, sublay mesh location is preferred, but open intraperitoneal onlay mesh (IPOM) may be useful in certain settings. This analysis of data from the Herniamed Registry aimed to compare the outcomes of open IPOM and sublay technique.MethodsPropensity score matching of 9091 patients with elective incisional hernia repair and with defect width  ≥ 4 cm was performed. The following matching variables were selected: age, gender, risk factors, ASA score, preoperative pain, defe...
Source: Hernia - Category: Sports Medicine Source Type: research
ConclusionThis retrospective study shows that mesh fixation in laparoscopic IPOM using cyanoacrylate glue with the Liquiband Fix8 ™ device is feasible, safe, easy to learn, and is associated with a low risk of seroma, hernia recurrence and chronic pain with short-medium term follow-up.
Source: Hernia - Category: Sports Medicine Source Type: research
ConclusionExperienced endoscopic laparoscopic hernia surgeons have the same or lower complication rates in TAPP therapy in complex inguinal and femoral hernias as in primary hernias with a high patient satifaction with the outcome of TAPP hernioplasty.
Source: European Surgery - Category: Surgery Source Type: research
This study evaluates the relationship of PA to outcomes after open ventral hernia repair (OVHR).MethodsA prospective institutional database was queried for patients undergoing OVHR. Demographics, operative characteristics, and outcomes were evaluated by the reported PA and the administration of beta-lactam prophylaxis (BLP).ResultsAllergy histories were reviewed in 1178 patients. PA was reported in 21.6% of patients, with 55.5% reporting rash or hives, 15.0% airway compromise or anaphylaxis, and 29.5% no specific reaction. BLP was administered to 76.3% of patients, including 22.1% of PA patients and 89.9% of patients witho...
Source: Surgical Endoscopy - Category: Surgery Source Type: research
Conclusion. Tension-free mesh repair in the treatment of emergency incarcerated groin hernia is safe and effective, which can reduce hernia recurrence without increasing infection risk. The results of biological mesh and PP mesh were comparable. PMID: 31994450 [PubMed - as supplied by publisher]
Source: Surgical Innovation - Category: Surgery Authors: Tags: Surg Innov Source Type: research
ConclusionOur study suggests that AF had a significantly improved hernia-specific quality of life in all domains at 30-days postoperatively. We also identified that pain as a binary variable is inadequate for its states purpose. Thus, the overall well-being and morbidity should be taken into account when evaluating hernia patients postoperatively.
Source: Hernia - Category: Sports Medicine Source Type: research
More News: Chronic Pain | Gastroschisis Repair | Hernia | Hernia Repair | Pain | Skin | Surgery