Precontoured buttress plate vs reconstruction plate for acetabulum posterior wall fractures: A biomechanical study.

CONCLUSION: PABP provides more stable fixation in acetabulum posterior wall fractures than 5-hole CCRP, allowing for proximal or distal fracture line screw application without reshaping. PMID: 31149562 [PubMed]