Unhas Suture, A Novel Tendon Repair Technique: An In Vitro Experimental Study Comparing Unhas Suture and Bunnell Suture in Tensile Strength and Gap Formation

Conclusions: Unhas suture was proven to be able to resist gap forces either in initial gap or 2-mm gap compared with Bunnell suture Clinical Relevance: Unhas suture may be a reliable alternative in tendon repair that provides tensile strength, gapping resistance and also provide easiness which can be performed with conventional suture material and less operating time.
Source: Techniques in Orthopaedics - Category: Orthopaedics Tags: Novel Research Methods and Models Source Type: research