Assessment of Critical Feeding Tube Malpositions on Radiographs Using Deep Learning

AbstractAssess the efficacy of deep convolutional neural networks (DCNNs) in detection of critical enteric feeding tube malpositions on radiographs. 5475 de-identified HIPAA compliant frontal view chest and abdominal radiographs were obtained, consisting of 174 x-rays of bronchial insertions and 5301 non-critical radiographs, including normal course, normal chest, and normal abdominal x-rays. The ground-truth classification for enteric feeding tube placement was performed by two board-certified radiologists. Untrained and pretrained deep convolutional neural network models for Inception V3, ResNet50, and DenseNet 121 were each employed. The radiographs were fed into each deep convolutional neural network, which included untrained and pretrained models. The Tensorflow framework was used for Inception V3, ResNet50, and DenseNet. Images were split into training (4745), validation (630), and test (100). Both real-time and preprocessing image augmentation strategies were performed. Receiver operating characteristic (ROC) and area under the curve (AUC) on the test data were used to assess the models. Statistical differences among the AUCs were obtained.p <  0.05 was considered statistically significant. The pretrained Inception V3, which had an AUC of 0.87 (95 CI; 0.80–0.94), performed statistically significantly better (p <  .001) than the untrained Inception V3, with an AUC of 0.60 (95 CI; 0.52–0.68). The pretrained Inception V3 also had the highest AUC overall,...
Source: Journal of Digital Imaging - Category: Radiology Source Type: research