Transobturator tape material detected in the bladder neck: a case report

ConclusionsEven though transobturator tape surgery is a safe and effective procedure for stress urinary incontinence, certain complications can be encountered. Misplacement of the mesh material through the bladder neck is a rare complication and can be managed by successfully removing the mesh material and appropriately placing new transobturator tape material.
Source: Journal of Medical Case Reports - Category: General Medicine Source Type: research