Predictability of Capillary Blood Spot Toward Venous Whole Blood Sampling for Therapeutic Drug Monitoring of Tacrolimus in Solid Organ Transplant Recipients

The objective of this literature review was to provide a critical evaluation on the feasibility (i.e., accuracy and precision) of DBS for predicting tacrolimus whole blood concentrations in solid organ transplant recipients. A comprehensive systematic literature search using PubMed, Scopus, EMBASE, and Google Scholar was conducted. The primary objective was to extract the bias and precision data from the identified papers. In addition, the collection, storage, and analysis protocols were also summarized. Both adult and pediatric data were included. The reported bias data (primarily based on individual concentrations) in the majority of studies were within acceptable limits (< 15%). However, the precision data were not consistently reported. The area under the concentration –time curve of tacrolimus derived from DBS appeared to be a better predictor of whole blood compared to single concentrations based on a limited number of studies. No apparent differences in prediction were observed between pediatric and adult patients. Small sample sizes and the lack of complete description of the study population were common limitations. DBS is a promising approach for tacrolimus TDM. However, in order for DBS to become a useful substitute for tacrolimus whole blood monitoring in solid organ transplant patients, further systematic studies with sufficient power and comprehe nsive prediction error analyses are required.
Source: European Journal of Drug Metabolism and Pharmacokinetics - Category: Drugs & Pharmacology Source Type: research